Use & Mixing

The instructions for use and mixing described below are from the Environmental Protection Agency approved Federal Label. Please click on 'Labels / MSDS' in the left hand navigation for special or state label instructions. Always read and follow label instructions.

Reason 500 SC (NY) Fungicide

Instructions
Mixing InstructionsPrepare no more spray mixture than is needed for immediate operation. Add approximately 1/2 of the required amount of water to the mix tank. Start the agitator running before adding the required amount of REASON 500 SC Fungicide. Continue agitation while filling the tank to ensure thorough mixing.Maintain agitation during application and apply with properly calibrated application equipment. Do not allow spray mixture to stand overnight or for prolonged periods. A high quality spreader/sticker, approved for use on growing crops, should be used with REASON 500 SC Fungicide. Do not use a spreader/sticker on carrots. REASON 500 SC Fungicide should be added to the tank before the addition of any adjuvant. Consult the adjuvant label or manufacturer for crop tolerance and safety information when used with REASON 500 SC Fungicide.
Reentry PPE
PPE required for early entry to treated areas that is permitted under the Worker Protection Standard and that involves contact with anything that has been treated, such as plants, soil, or water, is:long-sleeved shirt and long pants, shoes plus socks, and chemical resistant gloves made of any waterproof material, such as Nitrile, Butyl, Neoprene and/or Barrier Laminate.
PPE
PERSONAL PROTECTIVE EQUIPMENT (PPE)Applicators and other handlers must wear long-sleeved shirt and long pants, shoes plus socks, and chemical resistant gloves made of any waterproof material, such as Nitrile, Butyl, Neoprene and/or Barrier Laminate. Remove contaminated clothing and wash before reuse.Follow manufacturer's instructions for cleaning/maintaining personal protective equipment (PPE). If no such instructions for washables, use detergent and hot water. Keep and wash PPE separately from other laundry.When handlers use closed systems, enclosed cabs, or aircraft in a manner that meets the requirements listed in the Worker Protection Standard (WPS) for agricultural pesticides [40 CFR 170.240 (d) (4-6)], the handler PPE requirements may be reduced or modified as specified in the WPS.
Tankmix
CompatibilityREASON 500 SC Fungicide is compatible with most commonly used fungicide, herbicide, insecticide, and foliar nutrient products. However, the physical compatibility of REASON 500 SC Fungicide with all potential tank mix partners has not been fully investigated. If tank mixing with other pesticides is desirable, conduct a jar test with the volumes and rates typically used in agricultural application. Using a small container of water, add the proportionate amounts of the products, wettable powders and water-dispersible granular products first, then liquid flowables and emulsifiable concentrates last. Afterthoroughly mixing, let stand for at least 15 minutes. Look for signs of separation, globules, sludge, flakes, or other precipitates. Physical compatibility is indicated if the combination remains mixed or can be remixed readily. THE CROP SAFETY OF ALL POTENTIAL TANK MIXES WITH REASON 500 SC Fungicide, INCLUDING ADDITIVES AND OTHER PESTICIDES HAS NOT BEEN TESTED ON ALL CROPS.BEFORE APPLYING ANY TANK MIXTURE NOT SPECIFICALLY RECOMMENDED ON THIS LABEL, SAFETY TO THE TARGET CROP(S) SHOULD BE CONFIRMED.

Reason 500 SC

Instructions
Mixing Instructions Prepare no more spray mixture than is needed for immediate operation. Add approximately 1/2 of the required amount of water to the mix tank. Start the agitator running before adding the required amount of REASON 500 SC Fungicide. Continue agitation while filling the tank to ensure thorough mixing. Maintain agitation during application and apply with properly calibrated application equipment. Do not allow spray mixture to stand overnight or for prolonged periods. A high quality spreader/sticker, approved for use on growing crops, should be used with REASON 500 SC Fungicide. Do not use a spreader/sticker on carrots. REASON 500 SC Fungicide should be added to the tank before the addition of any adjuvant. Consult the adjuvant label or manufacturer for crop tolerance and safety information when used with REASON 500 SC Fungicide.
Reentry PPE
PPE required for early entry to treated areas that is permitted under the Worker Protection Standard and that involves contact with anything that has been treated, such as plants, soil, or water, is: long-sleeved shirt and long pants, shoes plus socks, and chemical resistant gloves made of any waterproof material, such as Nitrile, Butyl, Neoprene and/or Barrier Laminate.
PPE
PERSONAL PROTECTIVE EQUIPMENT (PPE) Applicators and other handlers must wear long-sleeved shirt and long pants, shoes plus socks, and chemical resistant gloves made of any waterproof material, such as Nitrile, Butyl, Neoprene and/or Barrier Laminate. Remove contaminated clothing and wash before reuse. Follow manufacturer's instructions for cleaning/maintaining personal protective equipment (PPE). If no such instructions for washables, use detergent and hot water. Keep and wash PPE separately from other laundry. When handlers use closed systems, enclosed cabs, or aircraft in a manner that meets the requirements listed in the Worker Protection Standard (WPS) for agricultural pesticides [40 CFR 170.240 (d) (4-6)], the handler PPE requirements may be reduced or modified as specified in the WPS.
Tankmix
Compatibility REASON 500 SC Fungicide is compatible with most commonly used fungicide, herbicide, insecticide, and foliar nutrient products. However, the physical compatibility of REASON 500 SC Fungicide with all potential tank mix partners has not been fully investigated. If tank mixing with other pesticides is desirable, conduct a jar test with the volumes and rates typically used in agricultural application. Using a small container of water, add the proportionate amounts of the products, wettable powders and water-dispersible granular products first, then liquid flowables and emulsifiable concentrates last. After thoroughly mixing, let stand for at least 15 minutes. Look for signs of separation, globules, sludge, flakes, or other precipitates. Physical compatibility is indicated if the combination remains mixed or can be remixed readily. THE CROP SAFETY OF ALL POTENTIAL TANK MIXES WITH REASON 500 SC Fungicide, INCLUDING ADDITIVES AND OTHER PESTICIDES HAS NOT BEEN TESTED ON ALL CROPS. BEFORE APPLYING ANY TANK MIXTURE NOT SPECIFICALLY RECOMMENDED ON THIS LABEL, SAFETY TO THE TARGET CROP(S) SHOULD BE CONFIRMED.
Always read and follow label instructions. Not all products are registered for use in every state. Please check with Bayer or your local Lead State Agency for product registration status. If you wish to find out if a product is registered in your state or for additional product information, send us an email or call 1-866-99-BAYER.
Reason

View all labels / MSDS

Discover why Crop Science, a Division of Bayer, is a market leader in the field of crop science. » more
Copyright © Bayer CropScience